Gas counters rotational RVG. Rotary gas meter RVG Gas meter rvg g160 passport

Gas counters rotational RVG. Rotary gas meter RVG Gas meter rvg g160 passport

6. Automation and secondary devices 7. Analytics

Teplopribor group of companies (GC) (Teplopribor, Prompribor, Teplokontrol, etc.)- these are devices and automation for measuring, controlling and regulating the parameters of technological processes (flow metering, heat control, heat metering, control of pressure, level, properties and concentration, etc.).

Products are shipped at the manufacturer's price as own production, and our partners - leading factories - manufacturers of instrumentation and control equipment, control equipment, systems and equipment for control technological processes- APCS (much is available in stock or can be manufactured and shipped as soon as possible).

RVG rotary gas meters

RVGrotary gas meters(G16; G25; G40; G65; G100; G160; G250; G400) are used for technological and commercial accounting of the volume of non-aggressive, dried and purified gases: natural and city gases, propane, air, nitrogen, inert gases, etc. in thermal power plants industrial, municipal and other enterprises.

Rotary gas meter RVG works on the principle of displacement of a strictly defined volume of gas by rotating rotors. The volume of the displaced gas is determined by the volume of the measuring chamber of the counter formed by the inner surface of the housing and the surfaces of two rotors rotating synchronously in opposite directions. The rotational movement of the rotors through the reducer and the magnetic coupling is transmitted to an 8-digit counting mechanism, which registers the number of revolutions of the rotors, and hence the volume of gas that has passed through the counter.

Gas meter RVG registers the volume of gas under operating conditions. To bring the measuring volume of gas to the volume at standard conditions counter RVG can be equipped with electronic correctors EK270, EK260 or TS220, TS215, TS210.

Distinctive features of the gas meterRVG

— Range of measured flow rates from 0.6 m³/h to 650 m³/h;

– Working gas pressure is not more than 1.6 MPa;

— Flow measurement range Q min / Q max: up to 1:160

— Temperature ranges:

environment from −40 to +70°С;

measured medium from −30 to +70°С;

— Limits of permissible relative error of the main version:

no more than ±1% in the range of costs from 0.1Q max to Q max;

no more than ±2% in the range of flow rates from Q min to 0.1Q max;

- Limits of permissible relative error of the additional version, which has the letter "U" in the designation:

no more than ±1% in the range of costs from 0.05Q max to Q max;

no more than ±2% in the range of flow rates from Q min to 0.05Q max;

- Calibration interval 5 years.

The main characteristics of the gas meterRVG

— high metrological characteristics;

— a wide range of measured costs;

— low pressure loss on the counter;

- speed and high accuracy pulse mode operation;

— lack of requirements for the length of straight sections, misalignment of the meter and the pipeline and the degree of non-circularity of the pipeline;

- installation on horizontal and vertical sections of the pipeline;

— independence of measurement accuracy from pressure and the nature of the gas flow in the network;

— the ability to work with electronic proofreaders EK270, EK260*, EK-88*, TS220, TS215*, TS210*, TS-90*;

— the possibility of using a high-frequency A1K and a mid-frequency R300 sensor in SG-EK complexes with an EK270 corrector to control gas flow;

- energy independence.

* - electronic correctors are out of production

Counter type Sensitivity threshold, m3/h Flow range, Qmax/Qmin Qmax, m3/h 2*LF(E1), imp/m3 (standard) HF(A1K), imp/m3 (optional) Differential P at Qmax, Pa
G16 0,1 1:30 25 10 14025 45
G25 0,1 1:30; 1:50; 1:65 40 10 14025 75
G40 0,1 1:30; 1:50; 1:65; 1:80 65 10 14025 180
G65 0,1 100 10 14025 390
G100 0,16 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 160 1 7528 390
G160 0,25 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 250 1 3882 525
G250 0,40 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 400 1 3187 975
G400 (Dy100) 0,65 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 650 1 2191 1100
G400 (Dy150) 0,65 1:30; 1:50; 1:65; 1:80; 1:100; 1:160 650 1 2191 1100

Two low-frequency pulse sensors E1 (reed contact), one of which, when working with an electronic corrector, is used to count pulses, the second - to provide the ability to control unauthorized intervention. By special order RVG gas meters are equipped with a medium-frequency sensor E300 and a high-frequency sensor A1K. Combination various types impulse sensors allows you to use gas meter RVG in systems of automatic regulation and control.

Rotary gas meters RVG are designed for commercial and technological accounting of volumes of flows of purified and dried gaseous media: natural gas, propane, hydrogen, air, nitrogen and inert gases.

Rotary meter RVG works on the principle of displacement of a strictly defined volume of gas by rotating rotors. The volume of the displaced gas is determined by the volume of the measuring chamber of the counter formed by the inner surface of the housing and the surfaces of two rotors rotating synchronously in opposite directions. The rotational movement of the rotors through the reducer and the magnetic coupling is transmitted to an 8-digit counting mechanism, which registers the number of revolutions of the rotors, and hence the volume of gas that has passed through the counter.

Gas meter The RVG registers the volume of gas under operating conditions. To convert the measuring gas volume to the volume under standard conditions, the RVG meter can be equipped on request with an electronic corrector of the or type.

Specifications:

Name
DN, mm
Qmax, m3/h
Pmax, MPa
Measuring range Qmin/Qmax
Threshold (m3/h)
Weight, kg
50 25 1,6 1:30 0,10 12
50 40 1,6 1:30, 1:50, 1:65 0,10 12
50 65 1,6 1:30, 1:50, 1:65, 1:80 0,10 12
50 100 1,6 1:30, 1:50, 1:65, 1:80, 1:100, 1:160 0,10 12
80 160 1,6 0,16 16
80 250 1,6 0,25 33
100 400 1,6 0,40 39
100, 150 650 1,6 0,40 50/56

Measuring complexes based on the RVG gas meter: (temperature correction) and (correction for temperature and pressure)


Main parameters:

  • The range of measured flow rates is from 0.8 m3/h to 650 m3/h;
  • Working gas pressure is not more than 1.6 MPa;
  • Flow measurement range Qmin / Qmax: up to 1:100 (up to 1:160 for G400)
  • Measurement error:

No more than ±1% in the flow rate range from 0.1Qmax to Qmax;

No more than ±2% in the range of flow rates from Qmin to 0.1Qmax;

  • Temperature ranges:

Rotary gas meter RVG is designed to measure volumes of purified and dried non-corrosive gases such as natural gas, city gas, propane, air, nitrogen, inert gases.

Purpose:

Technological and commercial accounting of the volume of non-aggressive, dried and purified gases: natural and city gases, propane, air, nitrogen, inert gases, etc. in heat power plants of industrial, municipal and other enterprises.

Available meter options and options for ordering:

RVG G16 Qmax=25 m³/h, Pmax=1.6 MPa, DN=50 mm, Qmax/Qmin

RVG G25 Qmax=40 m³/h, Pmax=1.6 MPa, DN=50 mm, Qmax/Qmin

RVG G40 Qmax=65 m³/h, Pmax=1.6 MPa, DN=50 mm, Qmax/Qmin

RVG G65 Qmax=100 m³/h, Pmax=1.6 MPa, DN=50 mm, Qmax/Qmin

RVG G100 Qmax=160 m³/h, Pmax=1.6 MPa, DN=80 mm, Qmax/Qmin

RVG G160 Qmax=250 m³/h, Pmax=1.6 MPa, DN=80 mm, Qmax/Qmin

RVG G250 Qmax=400 m³/h, Pmax=1.6 MPa, DN=100 mm, Qmax/Qmin

RVG G400 Qmax=650 m³/h, Pmax=1.6 MPa, DN=150 mm, Qmax/Qmin

Range extension (optional), Qmax/Qmin

Range extension (optional), Qmax/Qmin

Range extension (optional), Qmax/Qmin

Range extension (optional), Qmax/Qmin

Pulse sensor E1 IN-S10 for RVG S10 meters

Principle of operation:

Rotary gas meter RVG works on the principle of displacement of a strictly defined volume of gas by rotating rotors. The volume of the displaced gas is determined by the volume of the measuring chamber of the counter formed by the inner surface of the housing and the surfaces of two rotors rotating synchronously in opposite directions. The rotational movement of the rotors through the reducer and the magnetic coupling is transmitted to an 8-digit counting mechanism, which registers the number of revolutions of the rotors, and hence the volume of gas that has passed through the counter.

The RVG gas meter registers the volume of gas under operating conditions. To bring the measuring volume of gas to the volume under standard conditions, the RVG meter can be equipped with electronic correctors EK270, EK260, or TS215, TS210.

Distinctive features:

The range of measured flow rates is from 0.6 m3/h to 650 m3/h;
Working gas pressure is not more than 1.6 MPa;
Flow measurement range Qmin / Qmax:
up to 1:160
Temperature ranges:
environment from minus 40 to plus 700С;
measured medium from minus 30 to plus 700C;
Limits of permissible relative error of the main version:
no more than ±1% in the flow rate range from 0.1Qmax to Qmax;
no more than ±2% in the range of flow rates from Qmin to 0.1Qmax;
Limits of permissible relative error of the additional version, which has the letter "U" in the designation:
no more than ±1% in the flow rate range from 0.05Qmax to Qmax;
no more than ±2% in the range of flow rates from Qmin to 0.05Qmax;
Calibration interval 5 years.

Main characteristics:

high metrological characteristics;
a wide range of measured costs;
low pressure loss across the meter;
speed and high accuracy in the pulse mode of operation;
lack of requirements for the length of straight sections, misalignment of the meter and the pipeline and the degree of non-circularity of the pipeline;
installation on horizontal and vertical sections of the pipeline;
independence of measurement accuracy from the pressure and nature of the gas flow in the network;
the ability to work with electronic correctors EK270, EK260, EK-88*, TS210, TS215, TS-90*;
the possibility of using a high-frequency A1K and a mid-frequency R300 sensor in SG-EK complexes with an EK270 corrector to control gas flow;
energy independence.

*- electronic proofreaders are discontinued

Specifications:

Measuring range Qmax /Qmin 1: 30 (optional 1:50, 1:65, 1:80, 1:100, 1:160)
Measurement error: in the range from Qmin to 0.1 Qmax 2%
in the range from 0.1 Qmax to Qmax 1%
Sensitivity threshold 0.1 - 0.40 m3/h
Maximum operating pressure 1.6 MPa
Temperature range:
– environment from -30 °С to +70 °С
– measured medium from -20 °С to +60 °С
Calibration interval 5 years

Basic information:

Range of measured costs: from 0.6 m3/h to 650 m3/h

Flow measurement range Qmin / Qmax: up to 1:160

Calibration interval: 5 years

Price on request

Rotary gas meters are devices for measuring the volume of gas, the principle of their operation is based on the displacement of gas by rotors. They record the volume of gas under operating conditions.

To bring the measured value to a normal volume, electronic volume correctors of the EK-88, TS-90, EK-260 types are used. Gas flow range: from 0.8 m3/h to 400 m3/h. Maximum working pressure: 1.6 MPa.

Application area

Medium: natural gas, city gas, propane, inert gases, air. Industries: gas supply, thermal power, chemical industry. Tasks: measurement, control, automatic regulation.

Distinctive features

Over the years, RVG gas meters have proven themselves in operation, especially in cases where high measurement accuracy and compact design are required. Rotary gas meters type RVG are the ideal complement to turbine meters for flow rates from 0.8 m3/h to 400 m3/h. High quality design, component parts, materials guarantee high measurement accuracy, durability and reliability. RVG gas meters are equipped with two low-frequency pulse sensors E1 (reed contact). At the request of the customer, RVG gas meters are equipped with a medium-frequency pulse sensor E300 and a high-frequency sensor A1K. The combination of various types of impulse sensors allows the use of the RVG gas meter in automatic regulation and control systems.

RVG gas meters are distinguished by:

  • low inertia of rotors at variable loads (expenses);
  • low pressure loss (20 - 40 mm w.c.)

Installation and maintenance

Due to its principle of operation, the RVG gas meter does not require straight pipeline sections. Installation can be carried out both on a horizontal and on a vertical section of the gas pipeline. The oil level must be checked and maintained regularly. During operation, it is recommended to use filters or a conical sieve to trap particles larger than 0.25 mm. If the gas is very contaminated, then it is necessary to use an additional filter that traps particles larger than 0.05 mm.

Technical characteristics of industrial gas meters RVG

Counter type V (dm 3) Sensitivity threshold (m 3 / h) Qmin (m 3 /h) Qmin (m 3 /h)
G16 0,56 0,1 0,8 1,3
G25 0,56 0,1 0,8 2
G40 0,56 0,1 1 3,2
G65 0,56 0,1 1 5
G100 1,07 0,16 1,6 8
G160 2,01 0,25 2,5 13
G250 2,54 0,4 4 20
Qmax (m 3 /h) 2*LF (E1) (imp/m 3) (standard) MF (E300) (imp/m 3) (optional) HF (A1K) (imp / m 3) (additional) p(mbar) at Qmaxat nat. gases, \u003d 0.83 kg / m 3
25 10 200 14025 0,2
40 10 200 14025 0,5
65 10 200 14025 1,2
100 10 200 14025 2,6
160 1 20 7528 2,3
250 1 20 3882 2,9
400 1 20 3187 3,9

Rotary gas meterRVGG100 manufactured by "ELSTER Gaselectronics" is intended for measuring, collecting, storing and transmitting readings on the consumption of consumed natural gas or other working environment that cannot harm the meter parts. The counter is suitable for such gas environments as argon, nitrogen, air. The device must not be used for oxygen and hydrogen! Before gas enters the device, the working environment must be dried and cleaned. To use the device for commercial purposes (commercial accounting), it is possible to connect electronic correctors of the type EK 270, SPG 741 (761), TS 220, VKG 2. Due to the absence of the device electrical circuit it does not have explosion protection categories.

According to climatic version gas rvg counter g100 corresponds to category C according to GOST R 52931-2008.

Counter rvgg100 able work on a gas pipeline under gas pressure up to 1.6 MPa at a relative humidity of up to 95%. All specifications summarized in one table.

Specifications RVG G100.

Parameter name Parameter value
Working pressure, MPa, no more 1,6
Relative humidity up to, % 95
Ambient temperature, °С -40 +70
Working environment temperature, °С -30 +70
Relative measurement error, %
in the flow range from Qmin to 0.1Qmax ±2
in the flow range from 0.05Qmax to Qmax ±1.0
Calibration interval, years 5
Average service life, years, not less 12
The degree of protection of the meter against the ingress of dust and water IP54 according to GOST14254
Meter body material Aluminium alloy
Diameter conditional pass, mm 50
Dynamic measuring range 1:30
Maximum possible increase in measuring range 1:160

The sensitivity threshold of the device is a gas flow rate of 0.16 m3/hour. The counter has a counting mechanism with a capacity of 10 7 . The price of the division of the roller with the smallest digit is 0.1. The measuring chamber has a volume of 1.07.

The composition of the counter.

Structurally, a case can be distinguished from the composition of the counter, with two bases in which bearings are built. Rotors synchronously rotating by means of gears (2 pcs.). Multi-stage gearbox, magnetic clutch and counting mechanism. All parts that have direct contact with the working medium are made of a special aluminum alloy with an anti-corrosion coating.

The device and principle of operation of the RVG G100.

The basic principle of operation of the device is the displacement of a certain amount of gas by rotors that rotate in different sides. The amount of gas that is displaced by the rotors is calculated depending on the volume of the measuring chamber of the device. The measuring chamber is formed by the internal volume of the meter body and the surface of the rotors. Rotation from the rotors is received by a gearbox and a magnetic clutch, which in turn transmit further movement counting mechanism. The counting mechanism can be rotated by 355°. This greatly simplifies the reading of the instrument readings. To measure the inlet and outlet pressure, there are places on the device body for connecting pressure sensors. For temperature sensors, there are also places for installation. Gas filter, which must be installed in front of the meter in without fail, can be mounted directly to the meter.

The meter is checked every 5 years. Verification can only be carried out by specialized service centers or manufacturer. Meters can be installed both vertically and horizontally. G100 are produced with nominal bore 80mm.

Overall dimensions of the counter.

Dimensions, mm Weight
Dy Dk DL A B C E F H K L
80 160 8 M16 435 165 272 180 171 228 290 141 16

© 2023 globusks.ru - Car repair and maintenance for beginners